Alternate identifier:
-
Related identifier:
(Is Supplement To) 10.1002/cssc.202300779 - DOI
Creator/Author:
Fuchs, Martin [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Schäfer, Pascal M. [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Wagner, Wolf [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Krumm, Ian [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Walbeck, Marcel [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Dietrich, Regina [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]
Contributors:
-
Title:
Experimental Data to the publication "A Multitool for Circular Economy – Fast Ring-Opening Polymerization and Chemical Recycling of (Bio)polyesters Using a Single Aliphatic Guanidine Carboxy Zinc Catalyst"
Additional titles:
-
Description:
(Abstract) All NMR spectroscopic data, GPC data and Raman spectroscopic data for the ring opening polymerisation of lactide of a non toxic Zn catalyst were deposited. Furthermore, the NMR spectroscopic data for the depolymerisation of various polymers with the Zn complex were depostied.
Keywords:
NMR spectroscopy
lactide polymerisation
Depolymerisation
Raman spectroscopy
Related information:
-
Language:
English
Publishers:
RWTH Aachen University
Production year:
Subject areas:
Chemistry
Materials Science
Resource type:
(Dataset) NMR, GPC and Raman spectrosocpic experimental data
Data source:
(Instrument) Bruker Avance II (400MHz)
(Instrument) Bruker Avance III (400MHz)
(Instrument) GPCmax VE-2001 from Viscotek: two Malvern Viscotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 and 5000Å, a refractive index detector (VE-3580), and a viscometer (Viscotek 270 Dual Detector)
(Instrument) RXN1 spectrometer of Kaiser Optical System with a 785nm laser
Software used:
Resource production
Software:
TOPSPIN - 2-1
Alternative software:
-
Software used:
Resource production
Software:
iC Raman - V 4.1
Alternative software:
-
Software used:
Resource production
Software:
TOPSPIN - 3.5 pl 7
Alternative software:
-
Software used:
Resource processing
Software:
PEAXACT - 4.6
Alternative software:
-
Software used:
Resource production
Software:
Omnisec - 5.12
Alternative software:
-
Software used:
Resource processing
Software:
MestReNova - 12.0.1-20560
Alternative software:
-
Data processing:
-
Publication year:
Rights holders:
RWTH Aachen University
Funding:
European Commission - (sUstainable PLastIcs for the Food and drink packaging indusTry (UPLIFT))) H2020: 953073
Name Storage Metadata Upload Action

Number of views in the previous six months.

Dataset page views

214


Downloads

9


Overall statistics

Period Landing page accessed Dataset downloaded
Sep 2023 27 1
Aug 2023 34 1
Jul 2023 46 2
Jun 2023 70 5
May 2023 24 0
Apr 2023 13 0
Before 50 1
Total 264 10
Status:
Published
Uploaded by:
iac_Radar_Produktion
Created on:
Archiving date:
2023-02-10
Archive size:
50.2 MB
Archive creator:
iac_Radar_Produktion
Archive checksum:
16d9c601c972aefcb0bd713e4a9602ef (MD5)
Embargo end date:
-